The YACMF Series Coriolis Mass Flow Meter measures mass flow, density and temperature based on the Coriolis force principle, providing accurate and reliable measurement solutions for industries including petrochemical, chemical, pharmaceutical, food & beverage and energy.
Available in U-shaped, straight tube, triangular and micro-bend designs, the YACMF Series supports various process conditions. With a measuring range of DN3–DN300, accuracy up to ±0.1%, and multiple communication options including 4-20mA, Pulse, RS485 and HART, it meets modern industrial measurement requirements.
YACMF Series Coriolis Mass Flow Meter provides high-accuracy flow measurement for liquids and gases in industries such as petrochemical, natural gas, chemical processing and food & beverage. Based on the advanced Coriolis force principle, the YACMF Series Coriolis Mass Flow Meter directly measures mass flow, density and temperature with accuracy up to ±0.1%.
For straight-tube measurement with low pressure loss
For general industrial and demanding applications
For low-flow measurement and compact installations
For high-accuracy industrial flow measurement
Coriolis mass flow meters provide direct mass flow measurement with high accuracy and excellent stability. They can simultaneously measure mass flow, density and temperature, and are less affected by changes in fluid temperature, pressure and viscosity. With no requirement for long straight pipe runs, they are well suited for demanding industrial process applications.
The YACMF Series Coriolis Mass Flow Meter can be used for monitoring and measurement in a wide range of applications, meeting the requirements of batching, mixing, process control and commercial metering, including but not limited to the following industries.
Petroleum Industry
Pharmaceutical Industry
Paper Industry
Food Industry
Fuel Industry
Chemical Industry
Oil Industry
Coatings Industry
Transportation Industry
Textile & Printing Industry
Fine Chemical Industry
Boiler Industry
Metallurgical Industry
Power Industry
Water Conservancy Industry
Machinery Manufacturing Industry
New Energy Industry
New Materials Industry
Environmental Protection Industry
Military Industry
Mining Industry
Oil & Gas Industry
Shipbuilding Industry
Test Bench Industry
Energy Transfer Metering




The YACMF Series Coriolis Mass Flow Meter operates based on the Coriolis force principle. As fluid flows through the vibrating measuring tube, the mass flow causes a slight phase shift between the inlet and outlet sides of the tube. Sensors detect this phase difference and calculate the mass flow rate.
The meter can also determine fluid density from the vibration frequency of the measuring tube and measure temperature through an integrated temperature sensor, providing multiple process parameters in one instrument.
Higher accuracy measurement of 0.1%, 0.15%, 0.2%
Range ratio up to 1:50, small pressure loss
A wide range of applications, in addition to the normal fluid measurement, can also be measured by conventional instruments difficult to measure media, such as non-organic fluid, all kinds of slurry, high viscosity fluid, suspending liquid, gas
Easier installation, no upstream and downstream straight pipe section requirements
Reliable operation, stable and lower repair rate
Optional types include regular type, sanitary type, high-pressure type, ultra-high-temperature type, low-temperature type, insulated type, etc.
Nominal Diameter Range: DN3–DN300
Mass Flow Accuracy: ±0.1% to ±0.2%
Repeatability: ±0.05% to ±0.1%
Density Measurement Range: 0.3–3 g/cm³
Density Accuracy: ±0.002 g/cm³
Temperature Range: -250 to +350°C
Temperature Accuracy: ±1°C
Operating Ambient Temperature: -40 to +60°C
Measuring Tube Materials: SS316L, Hastelloy C, Titanium
Housing Material: SS304, SS316L
Working Pressure: Standard: 0–4.0 MPa; High-pressure version: 25–40 MPa
Explosion Protection: Ex db ia IIC T6 Gb
Protection Rating: IP67
Outputs: 4–20 mA, Pulse, RS485
Communication Protocols: RS485 Modbus, HART
Power Supply: 22–245 V AC/DC
LCD Display: Instantaneous flow rate, totalized flow, temperature, density, concentration, and other process parameters.
Data Retention: Supports data retention during power failure and data recovery after power restoration.
Converter Options: Integral converter or split-type converter.
The YACMF Series Coriolis Mass Flow Meter causes a certain amount of pressure loss during measurement. The pressure drop mainly depends on factors such as the measuring tube design, pipe size, flow rate, fluid density and viscosity.
In general, higher flow rates, smaller pipe sizes and more viscous fluids result in greater pressure loss. The YACMF Series is available in U-shaped, straight tube, triangular and micro-bend designs, allowing the appropriate structure to be selected according to different process conditions.
For applications sensitive to pressure drop, a suitable low-pressure-loss configuration can be selected based on the actual flow rate, medium and pipe size.
Yes. In addition to measuring mass flow, the YACMF Series Coriolis Mass Flow Meter can also measure fluid density and temperature.
The meter determines density by analyzing the vibration frequency of the measuring tube. This allows it to provide multiple process parameters in a single instrument and makes it suitable for applications such as chemical processing, food & beverage, petroleum, high-viscosity fluids and concentration-related measurement.
The YACMF Series can therefore provide mass flow, density and temperature measurement for a wide range of industrial process applications.
Coriolis mass flow meters are known for excellent long-term stability, but periodic zero-point checks and calibration are still recommended to maintain measurement accuracy.
For the YACMF Series Coriolis Mass Flow Meter, zero calibration should be performed under a no-flow condition with the measuring tube completely filled. Calibration intervals depend on the application, operating conditions and the required measurement accuracy.
For demanding applications or when measurement performance changes due to deposits, wear or process conditions, recalibration is recommended. Regular inspection and calibration help ensure stable and reliable long-term operation.

A modern production workshop built to international standards, equipped with comprehensive production, assembly, testing and calibration facilities, and certified to ISO9001, ISO14001 and ISO45001 management systems.

Copyright © 2026 YUA Instruments. All Rights Reserved.
Tell us about your application and measurement requirements.
Our technical team will recommend the right solution.