Product Advantages:Ultra-wide flow measuring range Measurement Range:0(0.1) … 250 Nm/s Turndown Ratio:1:2500
F212x flow meter is based on thermal measurement technology. It can measure the standard flow, mass flow, consumption, and gas temperature directly No moving parts, stable signal, vibration proof, high reliability, long-term measuring accuracy
Suitable for compressed air, nitrogen, oxygen, carbon dioxide, and other industrial gas flow measurement. Ideal for gas consumption monitoring, industrial process control, pipeline flow monitoring, and energy management systems.
| Flow | Display & Data log | ||
|---|---|---|---|
| Measuring Range | 0(0.1) … 250 Nm/s | Display | 2.8″ IPS LCD with capacitive touch |
| Accuracy | ±(1.5% RD + 0.3% FS) [1% RD Option] | Data Log | max. 10,000,000 values |
| Sampling Rate | > 20 Samples / sec | ||
| Medium | Compressed air, nitrogen, oxygen, Carbon dioxide & other non-condensing gases | ||
| Reference Conditions | 20 °C, 1 bar(a) -ISO 1217 (Configurable) | ||
| Output | Operating Environment | ||
| 4~20 mA Output (Standard) | Flow rate / Temperature (Configurable) | Environment Temperature | -30 … +70 °C |
| Pulse Output (Standard) | Consumption / Alarm | Medium Temperature | -40 … 150 °C |
| Digital Output (Standard) | Modbus RTU (RS485) | Operating Pressure | F212x: 0 … 1.7 MPa(a) (4.0 / 6.3 MPa.a Option) |
| Wireless Communication (Choose one of three) | Bluetooth (Default) Wi-SUN (Option) IOT-4G (Option) | ||
| Connector | 2 × 5pin M12, Female | ||
| Power | Other | ||
| Power | 18 … 30VDC 5W @ 24VDC | Process Connection | G1/2″ (ISO 228-1) (F211x Insert type) |
| EMC | Compliant with IEC 61326-1 | ||
| Pole / Pipe Section Material | SUS304 (Standard) SUS316 (Option) | ||



Copyright © 2026 YUA Instruments. All Rights Reserved.
Tell us about your application and measurement requirements.
Our technical team will recommend the right solution.