F211x Insert Type Thermal Mass Flow Meter

Product Advantages:Ultra-wide flow measuring range Measurement Range:0(0.1) … 250 Nm/s Turndown Ratio:1:2500

Leaflet

F211x flow meter is based on thermal measurement technology. It can measure the standard flow, mass flow, consumption, and gas temperature directly No moving parts, stable signal, vibration proof, high reliability, long-term measuring accuracy

Full-digital signal processing is used instead of the conventional analog bridge design, resulting in a wider range and more accurate measurement. The low measuring limit can reach 0.1Nm/s, and the turndown ratio can reach 1:2500. It has a wider measuring range than common flow meters on the market, making it suitable for measuring extremely volatile flow, low-flow bypass, and the gas consumption of single equipment. With the innovative, intelligent diagnosis technology, it can sense the sensor pollution online and protect the sensor fromoverheating
  • Full-digital signal processing, higher accuracy, long-term stability
  • Based on the thermal flow measurement principle, it’s not required to compensate gas pressure and temperature, integrated temperature measurement
  • With an ultra-wide 1:2500 turndown ratio, the measuring range is from 0.1 Nm/s to 250 Nm/s
  • The fully isolated electrical structure can completely filter out field disturbance
  • The capacitive touch 2.8″ IPS LCD with an ultra-wide viewing angle
  • Data logging function with max. 10,000,000 values
  • Bluetooth function for wireless flowmeter configuration and data transmission
  • Standard Modbus RTU (RS485) interface, 4 to 20 mA current and pulse output
  • Insert type F211x:
    Suitable for pipes with diameters from DN20 to DN1000, and can be installed under pressure via a 1/2″ ball valve

Suitable for compressed air, nitrogen, oxygen, carbon dioxide, and other industrial gases. Ideal for compressed air consumption monitoring, single-equipment gas measurement, low-flow detection, and industrial energy management systems.

FlowDisplay & Data log
Measuring Range0(0.1) … 250 Nm/sDisplay2.8″ IPS LCD with capacitive touch
Accuracy±(1.5% RD + 0.3% FS) [1% RD Option]Data Logmax. 10,000,000 values
Sampling Rate> 20 Samples / sec
MediumCompressed air, nitrogen, oxygen,
Carbon dioxide & other non-condensing gases
Reference Conditions20 °C,1 bar(a) -ISO 1217 (Configurable)
OutputOperating Environment
4~20 mA Output (Standard)Flow rate / Temperature (Configurable)Environment Temperature-30 … +70 °C
Pulse Output (Standard)Consumption / AlarmMedium Temperature-40 … 150 °C
Digital Output (Standard)Modbus RTU (RS485)Operating PressureF211x: 0 … 6.3 MPa
(>1.7 MPa.a High pressure jig required)
Wireless Communication (Choose one of three)Bluetooth (Default)
Wi-SUN (Option)
IOT-4G (Option)
Connector2 × 5pin M12, Female
PowerOther
Power18 … 30VDC 5W @ 24VDCProcess ConnectionG1/2″ (ISO 228-1) (F211x Insert type)
EMCCompliant with IEC 61326-1
Pole / Pipe Section MaterialSUS304 (Standard)
SUS316 (Option)
Leaflet_F211x-F212x_Thermal-Mass-Flow-Meter_YUA_EN_2024-V3.01-1.pdf315 KB
Download ↓
QG_F211x-F212x_Thermal-Mass-Flow-Meter_YUA_EN_2024-V2.01-1.pdf481 KB
Download ↓

CONTACT

Please input your name
Please input Email
Please input Tel
Please input Company
Please input Business
Please input needs
Please fill in the above information accurately. We will contact you as soon as possible!
×

Write to Us

Tell us about your application and measurement requirements.
Our technical team will recommend the right solution.