F211x-Ex Explosion-Proof Thermal Mass Flow Meter

Differential Pressure Flow Meter

F211x-Ex Explosion-Proof Thermal Mass Flow Meter

Gas lines rarely hold steady, so the F211x-Ex is built around a thermal sensor that reads mass flow directly rather than inferring it from a pressure drop, as a differential pressure flow meter or a pitot tube flow meter does. With no moving parts, a low limit of 0.1 Nm/s and a turndown ratio up to 1:2500, one insertion probe keeps reporting standard flow, mass flow, consumption and gas temperature across the working range.

F211x-Ex insertion thermal mass flow meter

One Insertion Probe, Four Gas Readings

The F211x-Ex is based on thermal measurement technology and directly measures standard flow, mass flow, consumption and gas temperature. A single installation point therefore covers the readings that would otherwise need several instruments.

Because the measurement follows the thermal principle, no gas pressure and temperature compensation is required, and gas temperature is captured integrally with the flow signal. The electrical structure is fully isolated so field disturbance is filtered out, and the display is a 2.0″ IPS LCD with capacitive touch and an ultra-wide viewing angle.

  • No moving parts. Stable signal, vibration proof, high reliability and long-term measuring accuracy.
  • Full-digital signal processing. Replaces the conventional analog bridge design, giving a wider range and more accurate measurement.
  • Intelligent diagnosis. Senses sensor pollution online and protects the sensor from overheating.
  • Complete data path. Data logging holds up to 10,000,000 values, with Bluetooth for wireless configuration and data transmission.
F211x-Ex thermal mass flow meter feature overview
F211x-Ex feature overview

Core Facts at a Glance

The numbers below come straight from the published product data for the F211x-EX insert type.

0.1 Nm/sLow measuring limit, so extremely volatile flow and low-flow bypass stay readable.
1:2500Turndown ratio across the working range.
DN20 – DN1000Pipe diameter coverage for the F211x-EX insert type.
IP67Protection code of the meter enclosure.
10,000,000Maximum number of values held by the data logging function.
2.0″ IPSCapacitive touch LCD with ultra-wide viewing angle.

F211x-Ex Specifications

Technical data for the insertion thermal mass flow meter, as published for this model.

Measuring range0(0,1) … 250 Nm/s
Turndown ratio1:2500
Low measuring limit0.1 Nm/s
Explosion-proof classEx db IIC T6 Gb / Ex tb IIIC T80°C Db
Protection codeIP67
Pipe diameter (insert type F211x-EX)DN20 to DN1000
Installation under pressurevia 1/2″ ball valve
Display2.0″ IPS LCD, capacitive touch, ultra-wide viewing angle
Data loggingmax. 10,000,000 values
Communications / outputsStandard Modbus RTU (RS485); 4 to 20 mA current; pulse output; Bluetooth
Measured variablesStandard flow, mass flow, consumption, gas temperature

The measuring range string is reproduced exactly as it appears in the published product data; the low measuring limit is stated separately as 0.1 Nm/s.

Where the F211x-Ex Fits

Three duties the meter is described as suitable for, plus the installation detail that makes them practical.

1

Extremely Volatile Flow

Where the gas flow swings quickly, the thermal sensor with a 1:2500 turndown ratio and full-digital signal processing keeps a readable signal instead of dropping out at the low end.

Low limit 0.1 Nm/s
2

Low-Flow Bypass

Small bypass lines are exactly where a wide turndown matters. The F211x-Ex is described as suitable for low-flow bypass measurement without pressure and temperature compensation.

Turndown ratio up to 1:2500
3

Single-Equipment Gas Consumption

Consumption is one of the four measured variables, so a dedicated meter can be fitted to one machine to track its own gas use rather than a shared header total.

Standard flow, mass flow, consumption, temperature

The insert type suits pipes from DN20 to DN1000 and can be installed under pressure through a 1/2″ ball valve.

Choosing the Right Configuration

Match the meter to the line, the flow profile and the area classification before ordering.

If the line cannot be shut down

Choose the insertion design. It fits pipes from DN20 to DN1000 and can be installed under pressure through a 1/2″ ball valve.

Insert type, pressure installation
If flow runs low or varies widely

Use the wide-range thermal measurement: a low limit of 0.1 Nm/s with a turndown ratio of 1:2500 keeps the low end of the scale usable.

0.1 Nm/s low limit · 1:2500
If the area is classified

Specify the explosion-proof version. The class is Ex db IIC T6 Gb / Ex tb IIIC T80°C Db, the protection code is IP67, and the structure carries a state-issued certificate.

Ex db IIC T6 Gb / Ex tb IIIC T80°C Db

Installation and Verification Points

The F211x-Ex is designed to be commissioned into a live line and then checked without pulling the probe. The points below are the ones worth confirming against your own site before the order is placed.

Before installation

  • Confirm pipe diameter falls within DN20 to DN1000 for the insert type.
  • Confirm a 1/2″ ball valve is available for installation under pressure.
  • Confirm the explosion-proof class matches the area: Ex db IIC T6 Gb / Ex tb IIIC T80°C Db.
  • Confirm the expected flow stays above the 0.1 Nm/s low limit.

After installation

  • Read standard flow, mass flow, consumption and gas temperature on the 2.0″ IPS touch display.
  • Verify the Modbus RTU (RS485), 4 to 20 mA and pulse connections at the control side.
  • Use Bluetooth for wireless configuration and data transmission.
  • Check the online sensor pollution diagnosis and the logging record, up to 10,000,000 values.
F211x insertion thermal mass flow meter installation diagram
F211 installation reference

Specify the F211x-Ex for Your Gas Line

Share your pipe diameter, expected flow range and area classification, and the F211x-Ex configuration can be confirmed against the published data for this model.

Useful details to include

  • Pipe diameter within DN20 to DN1000
  • Expected flow against the 0.1 Nm/s low limit
  • Area classification for the explosion-proof version
  • Preferred output: Modbus RTU (RS485), 4 to 20 mA or pulse
  • Whether Bluetooth configuration is required

Related Reading

Three notes to help clarify product requirements before contacting the supplier.

How Thermal Mass Flow Meters Measure Gas Without Pressure Compensation

A thermal mass flow meter reads gas mass directly from heat transfer, so it needs no separate pressure transmitter or temperature sensor to report mass or standard flow.

Read article

Insertion Thermal Mass Flow Meters for Compressed Air Networks – Your

Compressed air networks waste energy when nobody measures where the air goes. This guide explains main, branch, and equipment monitoring levels and where insertion thermal mass flow meters fit.

Read article

Hot Tap Installation of Insertion Gas Flow Meters in Live Pipes – Your

Hot tap installation lets maintenance teams add an insertion gas flow meter to a pressurized pipe without shutting the process down, and the ball valve is what makes that possible.

Read article

Frequently Asked Questions

what information is shown for this product?

review the product details, images, and specifications presented on the official product page.

where can i check the intended application?

use the application and use-case information published on the official product page.

which specifications should i confirm before ordering?

confirm the specifications and options listed for the exact product variant before placing an order.

where can i check available options?

check the official product page or ask the supplier about options shown for the selected product.

how can i request product information?

use the official contact or inquiry path provided on the site.

what should i include in an inquiry?

include the product page, intended use, required quantity, and any specifications you need the supplier to review.

CONTACT

Please input your name
Please input Email
Please input Tel
Please input Company
Please input Business
Please input needs
Please fill in the above information accurately. We will contact you as soon as possible!
×

Write to Us

Tell us about your application and measurement requirements.
Our technical team will recommend the right solution.